INTRODUCTION
APPLICATION
DESIGN AND OPERATION
MARKING AND
PACKING

OPERATING INSTRUCTIONS
General
Safety Precautions
Condition Checks
Preparation For Operation
Installation And
Wiring
Trobleshooting

OPERATING INSTRUCTIONS

PREPARATION FOR OPERATION
Prior to starting the motor check the rotor for free turning by hand. Start the motor at no load to check the condition of its mechanical part ( check for knocking, vibration, etc.) and sense of rotation. To alter the sense of rotation it is sufficient to interchange places of any two current-carrying leads. Prior to mounting clean the motor from dust and remove slushing grease surfaces. For the purpose make use of rags moistened with kerosene or gasoline. The motor must be reliably coupled to the driven mechanism to ensure normal transmission of rotary motion and properly fixed in position to prevent shocks and vibrations. To this end, mount the motor on a rigid foundation. The motor may be mounted on the body of the driven mechanism. When this is the case, take measures to ensure that the vibration speed of the unit at the joint ( at the motor foot or flange) is not to exceed the specified value. For the purpose, reinforce the driven mechanism body, reduce its unbalance, mount the motor or the whole unit on shock absorbers. Bear in mind that excessive thrust cause rapid wear of the bearings.